RV awning misting system: city water, fresh water pump and tank

Short answer

On campground water, tee the mister in after the RV's pressure regulator and filter, and set an adjustable regulator near 50 psi so an awning line still gets 45 psi or more. On the 12 V pump, a mister draws a few gallons per hour against a 3 GPM pump, so the pump stops and starts on its pressure switch, and the fresh tank empties at a rate you can work out: tank gallons divided by nozzle count times 0.5 GPH.

Key takeaways

  • On city water, the order is spigot, pressure regulator, filter, then a splitter: one leg to the RV, one to the mister. Go RVing says campground pressure can top 100 psi, and the mister kits read for this page are rated to 60 or 80 psi at most.
  • Regulators typically hold 30-50 psi. An awning line about 8 ft up loses about 3.5 psi to height, so 50 psi at the regulator leaves about 46.5 psi, just inside Orbit's 45-80 psi range. A 40 psi regulator does not reach it.
  • A SHURflo Revolution 4008 stops at 55 psi and restarts at 40 psi. A mister draws under 15 GPH, which by Pentair's own table is too little to hold the pump below its shut-off, so it cycles on the switch.
  • How often it cycles depends on the accumulator. Charged to 40 psi as Pentair advises, a 24 oz tank means about 124 starts an hour on a 5 GPH mister, and a 2 gallon tank about 12 (MistGuide calculation).
  • Fresh-tank runtime is gallons divided by nozzles x 0.5 GPH: a 30 gallon tank runs 10 nozzles for about 6 hours if nothing else uses water. The battery is not the limit: the pump uses roughly 0.08-0.23 amp-hours per gallon.

On campground water, connect an RV awning mister after the RV's pressure regulator and filter, with a splitter that sends one leg to the RV and one to the mister. Set an adjustable regulator near 50 psi. An awning line then still gets about 45 psi, which most hose-pressure kits need. On the 12 V fresh water pump, the mister works, but its flow is tiny next to the pump's. The pump stops and starts on its pressure switch, and the fresh tank empties at a rate you can work out before you leave.

This page gives the hookup order, the regulator settings that work, what a SHURflo Revolution 4008 pump does at mister flows, and a tank runtime table.

What do "city water", "regulator" and "demand pump" mean here?

An RV has two ways to pressurize its water lines, and a mister behaves differently on each.

  • City water is the campground spigot, connected by hose to the RV's city water inlet. The spigot's pressure drives everything. Go RVing says the RV's water pump should be off while you are on city water.
  • A pressure regulator is a small valve that screws onto the spigot. It cuts whatever pressure the campground supplies down to a set level. Go RVing calls it "an inexpensive and essential tool" and says the safe level is "typically between 30-50 psi, depending on the model."
  • A demand pump is the 12 V pump that draws from the fresh water tank when there is no hookup. A pressure switch runs it. When a faucet opens, pressure falls and the pump starts. When the faucet closes, pressure rises to the shut-off setting and the pump stops.

A mister is a faucet that never closes. Each nozzle is a tiny opening that lets water out all the time the line is on. That one fact explains most of what follows.

How do you hook an awning mister to campground water?

Put it at the end of the chain Go RVing already sets out for the RV itself:

  1. Regulator on the spigot. Go RVing warns that campground pressure "may exceed 100 psi, which could damage your RV's plumbing system." It is also more than the mister can take. Orbit rates most of its 3/8 in kits to 80 psi, and DripWorks specifies 40-60 psi for its backyard kit.
  2. Filter next. Go RVing says "the next item in the chain should be a water filter." Orbit calls a filter "highly recommended" for mist nozzles, because their tiny holes clog with debris and minerals. One filter here protects both the RV and the mister.
  3. Splitter after the filter. A hose Y-splitter with shutoffs sends one leg to the RV's white drinking water hose and one leg to the mister line. Each side can then be shut off on its own.
  4. Run the mister on its own hose to the awning. Keep the thin 1/4 in tubing for the nozzle line itself. A garden hose loses almost nothing at mister flows, while 1/4 in tubing used as a long feeder eats pressure, as how long a misting line can be shows.

There is a second way in. RV magazine describes one RV misting kit that can tap into city water, the RV's water filtration system, the exterior shower or the washer supply. An outdoor shower port sits downstream of both the city inlet and the pump, so a mister there works on either source. It sees whatever pressure the RV's lines carry at that moment.

Backflow devices for hose connections are covered in water supply and filtration.

What regulator setting does an awning mister need?

Enough to reach the nozzle minimum after the water climbs to the awning. Lifting water costs 0.433 psi per foot. An awning line about 8 ft above the spigot loses about 3.5 psi to height before any friction. Two kit ratings frame the answer: Orbit says most of its 3/8 in systems need 45-80 psi, and DripWorks rates its 1/4 in backyard kit at 40-60 psi.

Regulator setting against mister pressure ratings, for an awning line about 8 ft above the spigot (MistGuide calculation; line friction not included)
SupplyPressure at the awning lineDripWorks kit (40-60 psi)Orbit 3/8 in kits (45-80 psi)
Regulator at 30 psiAbout 26.5 psiBelow minimumBelow minimum
Regulator at 40 psiAbout 36.5 psiBelow minimumBelow minimum
Regulator at 45 psiAbout 41.5 psiInside rangeBelow minimum
Regulator at 50 psiAbout 46.5 psiInside rangeJust inside range
No regulator, spigot above 100 psiAbove 96 psiOver maximumOver maximum
SHURflo 4008 pump, 40-55 psiAbout 36.5-51.5 psi, swingingDips below minimum each cycleBelow minimum for part of each cycle

The ruling: use an adjustable regulator and set it at 50 psi, the top of Go RVing's typical range. Go RVing's own tip is "a brass, adjustable pressure regulator with a gauge." At 50 psi an Orbit-type kit runs, just. At 45 psi only a kit rated from 40 psi reaches its range. At 40 psi or below, neither kit reaches its minimum at awning height. Do not answer a weak mister by removing the regulator. The RV and the kit both need it.

The readings in the table are static. With water flowing, pressure at the nozzles is lower. Check by watching the last nozzle: if it drips or spits while the first ones mist, the line is short of pressure. The low-pressure misting systems guide covers the gauge test.

What does the 12 V pump do when only a mister is open?

It cycles. The SHURflo Revolution 4008 is a common RV pump, so its published numbers make a good example. Pentair's data sheet lists the 12 V model at 3 GPM open flow, shut-off at 55 psi and restart at 40 psi, each plus or minus 2 psi. (A 25 psi restart figure appears in some search snippets. Pentair's own data sheet says 40 psi.)

The 4008 also has an internal by-pass. Pentair's manual says it "is set to begin opening at about 40 psi," sending water back to the inlet side. The result, it says, is "smooth, steady flow with virtually no cycling, all the way down to a trickle." Sellers list the pump as "Internal Bypass-Low Cycling." So why would it cycle?

Because a mister is less than a trickle. Pentair's performance table gives 0.5 GPM at 50 psi and zero flow at 60 psi. Read between those rows, the pump reaches its 55 psi shut-off at about 0.25 GPM, or 15 GPH. Below that flow, pressure climbs to the switch and the pump stops. Pentair sets it up that way on purpose: its manual warns that if full by-pass comes before the shut-off setting, "the pump will not shut off."

A mister sits well below 15 GPH. Orbit lists its nozzles at 0.5 GPH each, so 10 nozzles draw 5 GPH. That is under 3% of a 3 GPM pump, which moves 180 gallons an hour. The pump fills the lines to 55 psi, stops, and restarts once the nozzles bleed pressure down to 40 psi.

How often does the pump start?

That depends on how much water is stored between 55 and 40 psi, and an accumulator is what stores it. An accumulator is a small tank with an air cushion inside. Pentair gives one rule for it. It "should be charged to the restart [On] pressure of the pump to provide the best system flow, low pump cycling and smooth performance." Shurflo's catalog lists a 24 oz nylon tank and a 2 gallon stainless tank.

Pump starts per hour on a SHURflo 4008 feeding only a mister, accumulator charged to 40 psi (MistGuide calculation)
MisterFlow24 oz accumulator2 gallon accumulator
6 nozzles x 0.5 GPH3 GPHAbout 74 starts/h (every 49 s)About 7 starts/h (every 8.6 min)
10 nozzles x 0.5 GPH5 GPHAbout 124 starts/h (every 29 s)About 12 starts/h (every 5.2 min)
20 nozzles x 0.5 GPH10 GPHAbout 248 starts/h (every 15 s)About 23 starts/h (every 2.6 min)

The table treats the air in the tank as following Boyle's law at constant temperature. Charged to 40 psi, an accumulator holds about 21.5% of its volume as water at 55 psi. That is about 5 oz in the 24 oz tank and about 0.43 gallon in the 2 gallon tank. Starts per hour are the mister's GPH divided by that amount. With no accumulator, only the stretch of the pipes and any trapped air store water, so the pump starts far more often than in either column.

The same swing sets the mist. With a charged accumulator, the line sits between 40 and 45 psi for about 39% of each cycle. At the awning, 3.5 psi lower, a 45 psi kit is short for longer than that. Even a 40-60 psi kit dips to about 36.5 psi at the bottom of each cycle. Expect the spray to coarsen as the pump nears its restart and sharpen again after it runs. If your pump uses a different switch range, the pump cycling and noise page explains what rapid cycling does to a pressure switch.

How long will the fresh water tank run a mister?

Divide the tank's gallons by the mister's gallons per hour. On an RV pump, no by-pass water leaves the system, so nozzle flow is the whole draw. The method is the same as in misting from a water tank. The table uses Orbit's 0.5 GPH per nozzle, a full tank, and nothing else drawing water.

Hours of continuous misting per full fresh water tank at 0.5 GPH per nozzle (MistGuide calculation)
NozzlesFlow20 gal30 gal40 gal60 gal100 gal
63 GPH6.7 h10 h13.3 h20 h33 h
105 GPH4 h6 h8 h12 h20 h
168 GPH2.5 h3.8 h5 h7.5 h12.5 h
2010 GPH2 h3 h4 h6 h10 h

These hours empty the tank. Subtract what you need for drinking, dishes and the toilet first, then run the mister on what is left. A cycle timer that mists half the time doubles every figure. Controllers, timers and humidistats covers cycle settings, and the water use calculator takes your own nozzle flow. Nozzles vary, so time one into a cup before trusting the 0.5 GPH figure.

The battery is rarely the limit. Pentair's table gives 1.2 GPM at 6.0 amps at 40 psi and 0.5 GPM at 6.8 amps at 50 psi. That works out to roughly 0.08-0.23 amp-hours per gallon pumped. A 5 GPH mister costs about 0.4-1.1 amp-hours an hour, and emptying a 30 gallon tank costs about 2.5-7 amp-hours. Other loads on a solar or battery setup are in solar and battery power for misting pumps.

Worked example: one awning, two water sources

Take an 18 ft awning with a 1/4 in mister line about 8 ft up, nozzles every 2 ft. That is 9 or 10 nozzles. Call it 10 at 0.5 GPH, so 5 GPH. The kit is an Orbit-type kit that wants 45 psi.

  • At a full-hookup site. The regulator is a fixed 40 psi model. The line gets about 36.5 psi, below the kit's 45. Swap to an adjustable regulator set at 50 psi and the line gets about 46.5 psi. Ten nozzles on 1/4 in tubing lose under 3 psi along the line, by the table in the line-length guide, so the far nozzle sits close to the minimum. It should mist, with little to spare.
  • Dry camping on a 30 gallon tank. On the 4008 pump with a 24 oz accumulator, the pump starts about every 30 seconds. The line swings between about 36.5 and 51.5 psi, so the mist coarsens for part of each cycle. Keeping 10 gallons back for the RV leaves 20 gallons, which is 4 hours of misting at 5 GPH. The battery gives up about 2-5 amp-hours over those 4 hours.

Same awning and same nozzles. On city water the regulator setting decides the result. On the pump the tank decides how long it lasts.

What should the mist stay away from?

  • The awning fabric, rolled up wet. Dometic's power awning manual says that whenever the awning is wet while rolled up, roll it out and let it dry "before rolling it up again. This will help prevent the formation of mildew." It adds that mildew forms "on the accumulated dust, dirt and grime," not the fabric itself. Lippert's manual says the same. Mount the line under the awning, aim the nozzles out and down, and let the awning dry before you roll it in. Dometic's warranty excludes damage from "rain, water pooling," so set the pitch for runoff as Lippert describes. The same warranty excludes "damage or failure caused by installation of accessories not manufactured and marketed by the Seller," so read yours before you drill a mister bracket into the awning arms. If the patio and chairs end up soaked, patio too wet covers the fixes.
  • Slide-out seals. Lippert says the main wipe seal on its In-Wall slide-outs "catches the majority of water" when it is properly engaged, and its drain channels must stay clear of dirt. A seal built to shed most of the rain is no reason to aim mist at it all afternoon. End the line short of the slide-out, or angle those nozzles away.
  • The RV's 120 V outlets. The National Electrical Code requires GFCI protection on 15 and 20 amp receptacles on the exterior of an RV (551.41(C) in the 2008 text). If the exterior outlet trips while the mist runs, the GFCI is doing its job: move the mist, do not bypass the outlet. A misting fan plugged in nearby falls under misting pump tripping a GFCI.

What does this page not cover?

It covers hose-pressure misters on an RV's own water: the campground spigot and the 12 V demand pump. The pump figures are for the SHURflo Revolution 4008 at 12 V. Another pump has its own shut-off, restart and flow table, so check its data sheet before you use the starts table. The regulator table counts height only, not friction, and uses static settings, so treat each row as the most the line can get. High-pressure 1,000 psi misting pumps have their own inlet rules, which the tank page covers. Pentair lists the 4008 motor as intermittent duty. Its manual says to shut off power to the pump "when leaving the RV unattended," so turn the mister off when you leave camp. Last, misting puts tank water on skin and into the air people breathe. Sanitize the fresh tank and drain the mister line as water hygiene and Legionella describes.

For the other installation guides, start at the installation section.

Frequently asked questions

Can I run an awning mister on the fresh water pump while boondocking?

Yes, within two limits. The pump holds only 40-55 psi, so a kit that needs 45 psi mists weakly for part of every cycle. And the tank sets your hours: a 10-nozzle line at 0.5 GPH each uses 5 gallons an hour. Pentair also says to shut off power to the pump when you leave the RV unattended, so do not leave the mister running while you are away.

Should the mister connect before or after the RV's water pressure regulator?

After it, and after the filter. Go RVing puts the regulator first in the chain and the filter next. A splitter after both gives the mister the same safe, filtered water the RV gets. Connected before the regulator, the mister could see campground pressure above 100 psi, past the 60-80 psi ratings of the kits read for this page.

Can I connect the mister to the RV's outdoor shower?

Yes, and it has one advantage: the outdoor shower sits downstream of both the city water inlet and the pump, so the mister works either way. RV magazine describes one RV misting kit that taps into city water, the water filtration system, the exterior shower or the washer supply. On the pump, expect the same 40-55 psi swing as any other fixture.

Do I need an accumulator to run a mister on the RV pump?

It is the one part that changes how the pump behaves. Pentair says an accumulator charged to the pump's restart pressure gives low pump cycling. Worked through for a 5 GPH mister, a 2 gallon tank cuts starts from about 124 an hour with a 24 oz tank to about 12. With none, the pump restarts far more often than either.

Why does my RV water pump keep turning on and off when the mister is running?

Because the mister is a small, steady leak by design. The pump fills the lines to 55 psi and stops. The nozzles bleed the pressure down to 40 psi and it starts again. That is normal at mister flows. If the pump cycles with the mister and every faucet closed, look for a real leak, which Pentair's troubleshooting lists first.

Sources and further reading

Figures on this page are cross-checked against the shared planning values in our research methodology. Where manufacturers publish different numbers, your equipment's data sheet takes precedence.

Spotted an error or an outdated figure? Tell us and see how we handle corrections.