Can you put fertilizer through a misting system?

Short answer

Yes, on a low-pressure propagation mist bench, at very low strength. Purdue's poinsettia guidance is 50 to 75 ppm nitrogen and potassium plus micronutrients, starting ten days after sticking, with no phosphorus. That is roughly 4.5 to 6.75 oz of a 15% nitrogen soluble fertilizer per 100 gallons, adding about 0.5 to 0.7 mS/cm of EC. Once fertilizer is in the line, it is chemigation, and the supply needs an air gap or a backflow assembly.

Key takeaways

  • Purdue's poinsettia propagation guide puts fertilizer into the mist from day 10 at 50 to 75 ppm nitrogen and potassium plus micronutrients, and says to use no phosphorus because foliar phosphorus can distort leaves.
  • 50 to 75 ppm N is 4.5 to 6.75 oz of a 15% N soluble fertilizer, or 3.4 to 5.1 oz of a 20% N one, per 100 gallons. On Plant-Prod's chart that adds about 0.48 to 0.72 mS/cm (15-0-15) on top of your water's own EC.
  • Too strong a solution, or too little mist to make it run off, leaves salt on the leaves and burns the margins (Cornell, 1962). The same bulletin saw no nozzle plugging or line corrosion after a year of mist feeding.
  • Water-powered injectors have a minimum flow (10 L/h on a Dosatron D14MZ2). A small bench can fall below it, so a premixed tank and pump is the simpler setup.
  • In Minnesota, fertilizer through irrigation is chemigation: a tank filled through a fixed air gap needs no permit, while a system tied to a well or surface water needs a permit and an RPZ or PVB tested every year.

Yes, you can put fertilizer through a propagation mist system. It has to be very dilute, and the supply has to be protected from backflow. Purdue Extension's poinsettia guide adds fertilizer to the mist ten days after sticking, at 50 to 75 ppm nitrogen and potassium plus micronutrients. It says to leave phosphorus out, because foliar phosphorus can distort leaves. That works out to about 4.5 to 6.75 oz of a 15% nitrogen soluble fertilizer per 100 gallons of water. Once fertilizer enters the line, regulators treat it as chemigation. The water supply then needs an air gap or a testable backflow assembly.

Two answers circulate. One says never, because fertilizer clogs nozzles and burns leaves. The other says growers have done it for decades. The second is right for low-pressure mist over cuttings, and the first describes what happens when the dose is too strong. A 1962 Cornell trial misted poinsettias with fertilizer for a year without plugging a nozzle. It also found that too strong a solution burned leaf margins.

What is nutrient mist, and why use it?

Nutrient mist (also called mist fertilization) is a propagation mist that carries a weak fertilizer solution instead of plain water. Every burst wets the cuttings, and some of the nutrients go into the leaves. The reason to do it is leaching. Cornell's Morton and Boodley wrote that leafy plants "readily lose stored mineral elements from their leaves when continually bathed with mist." Their cuttings could come off the bench yellow and short of nutrients. Purdue puts the cause in the media: "Media leaching from misting can lead to nutrient deficiencies."

Two other terms decide the answer. ppm N means milligrams of nitrogen per liter of the finished solution, which is how growers state fertilizer strength. EC (electrical conductivity) is what a conductivity meter reads. Dissolved fertilizer salts raise it, so it is a quick check on strength.

How strong should fertilizer in mist be?

Use 50 to 75 ppm nitrogen. That is the only mist-specific figure in a current extension guide read for this page. It is about a third of the 150 to 200 ppm Purdue uses when it waters cuttings instead. Purdue's guide gives two routes for poinsettia cuttings:

  • Through the mist: from day 10, 50 to 75 ppm nitrogen and potassium, plus micronutrients.
  • Through the media instead: water the cuttings every four or five days with 150 to 200 ppm nitrogen and potassium, plus micronutrients. This is a watering, not a mist. Do not run 150 to 200 ppm through the nozzles.

Purdue says to use no phosphorus fertilizers on either route. Cornell's 1962 trial used a complete 23-21-17, which has phosphorus, and did not report distortion. Follow Purdue. It is the newer guidance. The Cornell authors themselves wrote that "no definite recommendations can be made" from work still in progress.

The table converts the Purdue range into weights you can measure. The weights use the injector chart UMass Extension publishes from Griffin. The EC figures come from Plant-Prod's conductivity chart, read in distilled water. The 75 ppm EC is a MistGuide midpoint between the chart's 50 and 100 ppm rows.

Purdue's 50-75 ppm N mist strength converted to dose and added EC (MistGuide conversion of the UMass/Griffin and Plant-Prod charts)
Fertilizer typeDose for 50 ppm N, per 100 galDose for 75 ppm N, per 100 galEC added at 50 ppm NEC added at 75 ppm NFits Purdue's no-P rule?
15-0-154.5 oz (128 g)6.75 oz (191 g)0.48 mS/cmabout 0.72 mS/cmYes
15-0-204.5 oz (128 g)6.75 oz (191 g)0.45 mS/cmabout 0.68 mS/cmYes
20-0-203.4 oz (96 g)5.1 oz (144 g)0.43 mS/cmabout 0.65 mS/cmYes
20-20-203.4 oz (96 g)5.1 oz (144 g)0.23 mS/cmabout 0.35 mS/cmNo, contains phosphorus

Per gallon, 75 ppm N is about 1.9 g of a 15% N product or 1.4 g of a 20% N product. Weigh amounts that small on a gram scale. A spoon is too rough.

Two cautions on the EC column. First, add your tap water's own EC. Plant-Prod's method is to read plain water, read the solution, and subtract. Its chart also notes field readings can differ by about 10%. Second, urea barely shows on a meter. The same chart lists 20-20-20 at about half the EC of 20-0-20. Its 28-14-14 has 93% of its nitrogen as urea, and reads 0.16 mS/cm at 100 ppm N. For urea-heavy fertilizers, trust the weighed dose, not the meter.

What did the 1962 Cornell rate work out to?

About 69 ppm nitrogen, inside Purdue's range. Cornell mixed 4 oz of fertilizer per 100 gallons. Four ounces is 113 g, and 100 US gallons is 379 L. So the solution held 300 mg of product per liter. At 23% nitrogen, that is 69 ppm N. The urea bench used the same 4 oz. Urea is about 46% nitrogen, so that bench ran at about 138 ppm N.

Here is what each bench did. The 23-21-17 cuttings were 29.5% taller at potting than plain-mist cuttings. They bloomed 11 days earlier on average. The authors round that to two weeks in their discussion. The urea cuttings were 13.6% taller and bloomed four days earlier. Rooting grade was about the same in all three benches. They misted 10 seconds every 2.5 minutes on Barbara Ecke Supreme poinsettias.

What burns leaves under nutrient mist?

Salt left behind on the leaf. Cornell's warning names two causes. One is "too great a concentration." The other is "insufficient mist to effect runoff on the leaves." Either one lets salts build up on the leaf surface. That "can cause severe burning of the leaf margins, or indeed the whole leaf." The bulletin adds that the fertilizer "must be readily water soluble and nontoxic to the leaves."

So a nutrient mist needs bursts long enough to run off, not just dampen. That works against the usual habit of trimming bursts to keep media from getting soggy. The propagation mist systems guide gives the fix. Change the interval, and keep each burst long enough to wet leaves fully. If margins brown, check strength first, then runoff.

Does fertilizer clog mist nozzles?

Not at mist strength, in the one long trial read here. After a year of mist fertilization, Cornell reported "no corrosion of the water lines or plugging of the mist nozzles." The benches used "White Shower 100" mist nozzles, 38 in apart on 1 in lines. Finer nozzles are less forgiving. Aeroponic trials spray nutrient solution through very fine nozzles. There, the finest clogged about once per crop (see aeroponics interval, droplets and pressure).

What clogs a nutrient mist is mostly what clogs plain mist: particles, and minerals left as water dries. Fertilizer adds two risks of its own. One is undissolved product. The other is tank sediment. Purdue's checklist starts with making sure mist systems are "not clogged" before cuttings arrive. Five steps cover it:

  1. Use only fully soluble fertilizer. This is Cornell's rule. Dissolve it completely in the stock tank before it reaches the line.
  2. Keep the pickup off the tank floor. Dosatron's manual says to hang the suction strainer at least 4 in (10 cm) above the bottom. That keeps it from drawing up insoluble particles.
  3. Filter after the fertilizer goes in. Put the bench's own 100-200 mesh screen downstream of the injector. Then it catches anything the injector passes. Dosatron also wants a filter upstream to protect the injector. It requires 50 mesh (300 micron) where water carries particles and advises 300 mesh (60 micron).
  4. Treat hard water separately. Hard water scales nozzles with or without fertilizer in it. Test it and treat it as the hard water and water treatment guide describes.
  5. Rinse the injector with clean water when changing products. Dosatron says to draw about 1/4 liter of clean water through it.

If a nozzle does plug, the cleaning steps are in clogged misting nozzles.

Worked example: adding feed to a 4 x 8 ft mist bench

The bench: take the bench from the propagation guide. It has 8 nozzles at 1 GPH, misting 6 seconds every 6 minutes for 12 hours. That uses about 1.6 gallons a day. Suppose the target is Purdue's top figure, 75 ppm N, with a 15-0-15.

  1. Daily fertilizer: 1.6 gal x 1.9 g per gallon = about 3 g of product a day, about 0.45 g of nitrogen.
  2. Injector check: while misting, the bench flows 8 GPH, about 30 L/h. A Dosatron D14MZ2 lists a practical range from 10 L/h to 14 GPM. The bench is above the minimum.
  3. Concentrate at 1:100: the UMass/Griffin chart gives 9 oz per gallon of concentrate for 100 ppm with a 15% N product. For 75 ppm, use 6.75 oz. One gallon of concentrate makes about 100 gallons of mist, roughly two months of this bench.
  4. Half the bench: now suppose only 4 nozzles of 0.5 GPH are on that zone. That is 2 GPH, about 7.6 L/h. It is below the injector's 10 L/h minimum, so the dose would not be reliable.
  5. The small-bench answer: mix the solution in a tank instead. Five gallons at 1.9 g per gallon is about 9.5 g of fertilizer. A small pump feeds the bench from the tank, as the Cornell benches were fed.

What this tells you: mist uses so little water that a feed costs grams a day. The injector is the hard part, not the fertilizer. Cornell saw the same thing in 1962. Proportioners "operate on a minimum flow value." With one or two benches on mist, the minimum "may not be met." For small installations, "a direct pump operation is probably best." Pump and tank setups are covered in misting from a water tank.

What backflow protection does fertilizer in a mist line need?

Once the line carries fertilizer, it is a chemical hazard to the water supply. Minnesota's guideline is the one rule text read for this page. It defines chemigation as applying "fertilizer and/or pesticide" to greenhouse or nursery crops "during the irrigation process." A mist bench that carries fertilizer fits that definition.

Minnesota greenhouse chemigation rules, as stated in the MDA 2024 antipollution device guideline
SetupPermitDevice the guideline names
Stand-alone tank filled through a fixed air gapNot requiredAir gap at least 2 times the outlet diameter, outlet permanently fixed (a 2 in line at least 4 in above the fill opening)
System connected to groundwater or surface waterChemigation permit requiredRPZ or PVB, installed by a licensed plumber, tested after installation and at least once a year
Pump-injected system on municipal or potable waterPermit requiredRPZ as the main device
Pump-injected system on a non-potable wellPermit requiredPVB allowed

An air gap is open air between the end of the fill pipe and the top of the tank. Tank water cannot be drawn back across it. An RPZ (reduced pressure zone assembly) is two check valves with a relief valve between them that dumps water if either check leaks. The guideline's definition of antipollution devices also names check valves, vacuum relief valves, interlocks and low-pressure shutdowns. Those are examples of what counts. They are not a list it requires for greenhouses. Supply tanks may need extra safeguards if they hold over 1,500 gallons. The same goes for a tank within 100 feet of a well for more than 30 consecutive days.

A tank filled through an air gap and pumped to the bench is Cornell's small-bench setup. In Minnesota it is also the one that needs no permit. Dosatron's manual adds two siphon rules. Never let the stock solution sit above the injector's water inlet. Never mount the injector on the suction side of a pump. For automatic systems it says slow opening and closing solenoid valves are preferable, as part of its water hammer advice. How the device classes compare is in backflow prevention for misting systems.

Should you feed through your mist? Quick rulings

Rulings from this page and their sources
SituationRulingSource
Leafy cuttings under low-pressure mist, day 10 onward50-75 ppm N and K plus micronutrients, no phosphorusPurdue HO-235-W
You would rather not inject into the mistWater the media with 150-200 ppm N and K every 4-5 daysPurdue HO-235-W
Checking strength with a meterSubtract tap water EC; expect about 0.48-0.72 mS/cm added for 15-0-15Plant-Prod chart
Urea-heavy fertilizerCheck by weighed dose; EC reads far too lowPlant-Prod chart
Leaf margins burningLower the strength, or lengthen bursts so leaves run offCornell Bulletin 203
Zone flow below the injector's minimumPremix in a tank and pump it to the benchCornell Bulletin 203; Dosatron manual
Tank filled through a fixed air gap (Minnesota)No chemigation permitMDA 2024
Injector tied to a well or surface water (Minnesota)Permit, plus RPZ or PVB tested yearlyMDA 2024

What this answer does not cover

The strength figures come from poinsettia cuttings on low-pressure mist. Purdue's guide is written for poinsettia, and Cornell tested one cultivar. Other crops may take more or less, and nothing read here gives a ceiling EC for mist on any crop. The 50-75 ppm range is not a safe limit for every plant. Watch the first batch for margin burn. The figures do not apply to high-pressure fog. Fog usually runs on reverse osmosis water, because every dissolved solid lands on leaves, glazing or nozzles. They do not apply to patio misting either. Pesticides through a mist line raise the hazard further and carry their own label and state rules. The legal table is Minnesota only. Your state, water utility or plumbing inspector decides which device your connection needs. Confirm it before you connect an injector to a potable line. For the rest of the bench, start with propagation mist systems; other topics are on the greenhouses hub.

Frequently asked questions

Can I add fertilizer to a hose-end patio misting kit for my hanging baskets?

The concentrations on this page come from propagation benches, where the mist is meant to wet leaves and run off. A patio kit aims for droplets that evaporate before landing, which leaves the fertilizer salts on whatever they reach: plants, furniture, glass and people. No source read here tested that use. Feed baskets through the soil instead, and keep the misting line on plain water.

What EC should a nutrient mist read on my meter?

Measure your plain water first, then the mist solution, and subtract. The difference is the fertilizer. For a no-phosphorus 15-0-15 at 50 to 75 ppm nitrogen, Plant-Prod's chart puts that difference at about 0.48 to 0.72 mS/cm. The chart was made with distilled water, and the maker says field readings can vary by about 10%. Fertilizers heavy in urea read far lower, so check those by weighed dose.

Should the mist feed run all day or only on some bursts?

The sources read here fed every burst. The 1962 Cornell trial misted fertilizer solution 10 seconds every 2.5 minutes for the whole rooting period, and Purdue simply says to incorporate fertilizer into the mist system from day 10. Neither describes pulsing feed on only some bursts. If you want feed on fewer bursts, Purdue's other route is plain mist plus a 150 to 200 ppm watering every four or five days.

Does a hose bib vacuum breaker count as backflow protection for a fertilizer injector?

Not under the Minnesota guideline read here. It names three options for a chemigation supply: a fixed air gap, a reduced pressure zone assembly, or a pressure vacuum breaker, and the PVB only on a non-potable well. Pump-injected systems on municipal or potable water must have an RPZ. A hose bib vacuum breaker is not on that list. Other states set their own rules, so ask the local plumbing inspector.

Will fertilizer in the mist cause algae on the bench?

None of the sources read for this page measured algae under nutrient mist. Purdue's propagation guide does tell growers to clean the area of algae before cuttings arrive. Nutrients on a constantly wet surface are a reasonable thing to watch for. Keep the stock tank covered and opaque, clean the bench between crops, and treat green film on media or bench as a sign to review sanitation.

Sources and further reading

Figures on this page are cross-checked against the shared planning values in our research methodology. Where manufacturers publish different numbers, your equipment's data sheet takes precedence.

Spotted an error or an outdated figure? Tell us and see how we handle corrections.