<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"><channel>
<title>MistGuide</title><link>https://mistguide.com/</link><description>Independent guides to misting systems, nozzles, pumps and evaporative cooling</description><language>en-us</language>
<item><title>Misting pump runs but no mist comes out: what to check</title><link>https://mistguide.com/troubleshooting/pump-runs-but-no-mist/</link><guid>https://mistguide.com/troubleshooting/pump-runs-but-no-mist/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>If a misting pump runs but no mist appears, the pressure gauge tells you where to look. Near zero pressure means the pump is not getting water, has lost prime, or the unloader is bypassing everything. High pressure with no mist means the water is blocked downstream by a closed valve, a kink or clogged nozzles. Stop a plunger pump immediately if it is running dry.</description></item>
<item><title>Misting pump cycling and noise: pulsing, knocking, cavitation and chatter</title><link>https://mistguide.com/troubleshooting/pump-cycling-and-noise/</link><guid>https://mistguide.com/troubleshooting/pump-cycling-and-noise/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Most misting pump noise comes from a starved inlet (cavitation that sounds like gravel), an unloader or bypass valve hunting because nozzle demand is close to pump output, a small leak making a pressure-switch pump short cycle, or vibration from loose mounts. Clean the inlet filter and confirm supply first, then check for leaks, the unloader and the mounting.</description></item>
<item><title>Misting system making the patio too wet? Causes and fixes</title><link>https://mistguide.com/troubleshooting/patio-too-wet/</link><guid>https://mistguide.com/troubleshooting/patio-too-wet/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A patio gets wet when mist falls faster than the surrounding air can evaporate it. The usual causes are a low-pressure system that makes large droplets by design, a high-pressure system running below about 600-700 psi, nozzles mounted too low or aimed at people, too much nozzle flow for the space, high humidity, or still air under a roof. Fix pressure first, then height, flow and air movement.</description></item>
<item><title>Why are my misting nozzles dripping? Ranked causes and fixes</title><link>https://mistguide.com/troubleshooting/misting-nozzles-dripping/</link><guid>https://mistguide.com/troubleshooting/misting-nozzles-dripping/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Nozzles that drip after shutoff are usually draining the water left in the line, either because they have no anti-drip check or the check has failed or scaled open. Nozzles that drip while running usually have a partial clog, worn orifice or too little pressure to atomize. Drips at the nozzle base, not the tip, are a seal leak.</description></item>
<item><title>Low pressure or pressure loss in a misting system: diagnosis and fixes</title><link>https://mistguide.com/troubleshooting/low-pressure-or-pressure-loss/</link><guid>https://mistguide.com/troubleshooting/low-pressure-or-pressure-loss/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Low pressure in a misting system usually comes from a clogged inlet filter or weak water supply, more total nozzle flow than the pump can deliver, a leak or missing nozzle, or an unloader that is set low or worn. In a high-pressure system, pressure is set by how much flow the nozzles let through, so extra nozzles or worn orifices lower it directly.</description></item>
<item><title>Leaking misting system fittings: how to find and fix them</title><link>https://mistguide.com/troubleshooting/leaking-fittings/</link><guid>https://mistguide.com/troubleshooting/leaking-fittings/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Most misting fitting leaks come from tubing that is not fully inserted, a cut that is angled, scored or burred, a damaged or missing O-ring, or a thread mismatch at the nozzle. On high-pressure lines, depressurize before touching anything and locate leaks with cardboard, never your hand, because a pinhole jet at 1,000 psi can inject water through skin.</description></item>
<item><title>Clogged misting nozzles: how to diagnose, clean and prevent them</title><link>https://mistguide.com/troubleshooting/clogged-misting-nozzles/</link><guid>https://mistguide.com/troubleshooting/clogged-misting-nozzles/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Misting nozzles clog from two main sources: mineral scale from hard water, which builds gradually on all nozzles, and particles such as installation debris, rust or sediment that get past or around the filter, which block a few nozzles suddenly. Soak clogged tips in white vinegar or citric acid overnight, never poke them with a pin, and fix the water source or filter so it does not recur.</description></item>
<item><title>Are mosquito misting systems legal where you live, and can you add insecticide to a patio mister?</title><link>https://mistguide.com/systems/mosquito-misting-legality/</link><guid>https://mistguide.com/systems/mosquito-misting-legality/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>It depends on your state and on the pesticide label, not on the equipment. Connecticut and Illinois ban residential automatic pesticide misting systems outright, New York treats any product usable in one as restricted use, Wisconsin allows them under chemigation rules, and some states have no misting-specific rule at all. Adding insecticide to a patio cooling mister is illegal unless the product label permits misting-system use.</description></item>
<item><title>Misting vs fogging: what actually separates them</title><link>https://mistguide.com/systems/misting-vs-fogging/</link><guid>https://mistguide.com/systems/misting-vs-fogging/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Fogging and misting both atomize water for evaporative cooling or humidity, but fog uses droplets under roughly 10-20 microns that stay suspended and evaporate without wetting surfaces, while mist uses larger droplets that can settle and wet. Fog usually needs 1,000-1,500 psi or ultrasonic or centrifugal atomizers, plus very clean water.</description></item>
<item><title>Misting system cost: what you will pay upfront and every season</title><link>https://mistguide.com/systems/misting-system-cost/</link><guid>https://mistguide.com/systems/misting-system-cost/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Low-pressure misting kits cost about $20-$100, mid-pressure pump kits about $150-$600, and high-pressure DIY kits about $400-$2,000+, with professional residential installs often $2,000-$6,000+. Running costs are mostly water: a 20-nozzle high-pressure system uses about 180 gallons in 6 hours, while its pump uses roughly 1.2-3 kWh.</description></item>
<item><title>Misting in humid climates: when it works, when it fails, what to do instead</title><link>https://mistguide.com/systems/misting-in-humid-climates/</link><guid>https://mistguide.com/systems/misting-in-humid-climates/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Misting works poorly in humid climates because the air is already close to its wet-bulb limit and misting adds more moisture. In Houston at 95°F and 55% RH, good high-pressure misting can lower air temperature about 8°F, but the heat index only falls from about 109 to 103. Above about 65-70% RH, fans and shade usually help more than mist.</description></item>
<item><title>Mid-pressure misting systems: the middle ground explained</title><link>https://mistguide.com/systems/mid-pressure-misting-systems/</link><guid>https://mistguide.com/systems/mid-pressure-misting-systems/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A mid-pressure misting system uses a small diaphragm booster pump to raise water to about 100-300 psi, usually in the 160-250 psi class, producing droplets of roughly 20-50 microns. It cools noticeably better and wets less than a hose-pressure kit, costs far less than a 1,000 psi plunger pump system, and suits small patios, misting fans and portable setups.</description></item>
<item><title>Low-pressure misting systems: honest expectations and best setup</title><link>https://mistguide.com/systems/low-pressure-misting-systems/</link><guid>https://mistguide.com/systems/low-pressure-misting-systems/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A low-pressure misting system runs on ordinary household or hose pressure (40-80 psi) with no pump. Its droplets are roughly 50-100+ microns, so much of the water lands before evaporating. Expect a modest cooling of about 6-12°F in very dry heat, noticeable wetting, and little benefit in humid weather. It costs about $20-$100.</description></item>
<item><title>How misting systems work: the physics of evaporative cooling</title><link>https://mistguide.com/systems/how-misting-systems-work/</link><guid>https://mistguide.com/systems/how-misting-systems-work/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A misting system cools by evaporation: each gallon of water that turns to vapor absorbs roughly 8,700 BTU of heat from the surrounding air. The air can never be cooled below its wet-bulb temperature, so the achievable drop depends on how dry the air is. Fine droplets evaporate faster, and fans spread the cooled air to people.</description></item>
<item><title>High vs mid vs low pressure misting systems compared</title><link>https://mistguide.com/systems/high-vs-mid-vs-low-pressure/</link><guid>https://mistguide.com/systems/high-vs-mid-vs-low-pressure/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>High-pressure misting (800-1,000 psi) makes the finest droplets, cools the most and stays driest, but costs the most. Mid pressure (about 100-300 psi) is a lower-cost middle ground that suits fans and small patios. Low pressure (40-80 psi) is cheap and simple but wets surfaces and cools least. Dry climates reward higher pressure most.</description></item>
<item><title>High-pressure misting systems: the complete guide</title><link>https://mistguide.com/systems/high-pressure-misting-systems/</link><guid>https://mistguide.com/systems/high-pressure-misting-systems/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A high-pressure misting system uses a plunger pump to push water through tiny nozzles at 800-1,000 psi, producing droplets of roughly 5-20 microns that evaporate before they land. It delivers the most cooling and least wetting of any misting class, but needs a 5-micron filter, pressure-rated tubing and a pump sized to the nozzle count.</description></item>
<item><title>Misting droplet size explained: microns, evaporation and the claims</title><link>https://mistguide.com/systems/droplet-size-explained/</link><guid>https://mistguide.com/systems/droplet-size-explained/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Droplet size, measured in microns, decides whether mist cools the air or wets surfaces. Evaporation time grows with roughly the square of droplet diameter, so a 10-micron droplet vanishes about 100 times faster than a 100-micron one. Manufacturers quote different statistics, such as count mean, Sauter mean diameter (D32) or Dv50, which is why claims for similar nozzles can differ several-fold.</description></item>
<item><title>Unloaders, bypass regulators and pressure control for misting pumps</title><link>https://mistguide.com/pumps/unloaders-and-pressure-regulation/</link><guid>https://mistguide.com/pumps/unloaders-and-pressure-regulation/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A plunger misting pump pushes a fixed flow, so it needs a valve to handle what the nozzles cannot take. A bypass regulator holds a set pressure (usually about 1,000 psi) by diverting excess flow; a true unloader drops the pump to low pressure when flow stops. Set pressure on a gauge with all nozzles installed, and add a dump valve to stop drips at shutdown.</description></item>
<item><title>Misting pump placement, noise control and power supply</title><link>https://mistguide.com/pumps/pump-placement-noise-and-power/</link><guid>https://mistguide.com/pumps/pump-placement-noise-and-power/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Put a misting pump close to its water supply and outlet, in shade, off the ground, ventilated and away from seating. High-pressure lines lose little pressure over distance, so moving the pump 50 ft away costs only a few psi. Power it from a GFCI-protected outdoor outlet, avoid long light-gauge extension cords, and expect a small residential pump to cost tens of dollars per season to run.</description></item>
<item><title>Plunger vs diaphragm misting pumps: how they differ and which to choose</title><link>https://mistguide.com/pumps/plunger-vs-diaphragm-pumps/</link><guid>https://mistguide.com/pumps/plunger-vs-diaphragm-pumps/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Choose a plunger pump if you want true high-pressure misting at 800-1,000 psi with droplets of roughly 5-20 microns and long daily run times. Choose a diaphragm pump for a cheaper, simpler mid-pressure system at about 100-300 psi, accepting larger droplets (roughly 20-50 microns) and more wetting.</description></item>
<item><title>Misting pump guide: pump types and how to read a data sheet</title><link>https://mistguide.com/pumps/misting-pump-guide/</link><guid>https://mistguide.com/pumps/misting-pump-guide/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A misting pump is rated mainly by flow (GPM) at a stated pressure (psi). For high-pressure misting you want a plunger pump that delivers its rated GPM at 1,000 psi, a motor sized for that load, low rpm, a head material matched to your water, and inlet requirements your supply can actually meet.</description></item>
<item><title>How to size a misting pump: the step-by-step method</title><link>https://mistguide.com/pumps/how-to-size-a-misting-pump/</link><guid>https://mistguide.com/pumps/how-to-size-a-misting-pump/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Add up the flow of every nozzle that runs at the same time, then choose a pump that delivers at least that flow divided by 0.80-0.85 at your operating pressure. Example: 16 nozzles of 0.012 in at 0.025 GPM need 0.40 GPM, so a 0.5 GPM pump at 1,000 psi fits with 20% headroom.</description></item>
<item><title>Restaurant and commercial patio misting: comfort, dry tables and water safety</title><link>https://mistguide.com/patios/restaurant-and-commercial-patios/</link><guid>https://mistguide.com/patios/restaurant-and-commercial-patios/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A restaurant patio misting system should be high pressure (800-1,000 psi), zoned by seating area, controlled by humidity and wind, and run under a written water management routine. Most guest complaints about wet tables come from low pressure, oversized or worn nozzles, drips at shutoff, or misting into humid evening air.</description></item>
<item><title>Misting systems for pool decks and outdoor kitchens</title><link>https://mistguide.com/patios/pools-and-outdoor-kitchens/</link><guid>https://mistguide.com/patios/pools-and-outdoor-kitchens/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Misting works well around pools and outdoor kitchens if you give the grill and any TV their own dry zone, keep nylon tubing away from grill heat, avoid misting walkways and steps, and treat hard water if glass fences or doors are nearby. Pool chlorine is irrelevant: the mist comes from the house supply, and drift into the pool is negligible.</description></item>
<item><title>Patio misting system design guide: a step-by-step planning method</title><link>https://mistguide.com/patios/patio-misting-design-guide/</link><guid>https://mistguide.com/patios/patio-misting-design-guide/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Design a patio misting system in seven steps: measure the seating zone and mounting points, check design-day humidity, map afternoon wind, choose a pressure class, place nozzles 18-24 in apart at 8-10 ft on the upwind edge, split long runs into zones, and size the pump to the largest zone with 15-20% headroom.</description></item>
<item><title>Misting covered patios and pergolas: mounting, fans and airflow</title><link>https://mistguide.com/patios/covered-patios-and-pergolas/</link><guid>https://mistguide.com/patios/covered-patios-and-pergolas/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>On a covered patio or pergola, run the misting line along the perimeter beam on the open, upwind sides at 8-10 ft, never across the middle over tables. Keep at least two sides open so humid air can escape, keep nozzles clear of awning fabric and louver blades, and run ceiling fans at low speed so they spread cooled air instead of pushing mist onto surfaces.</description></item>
<item><title>Misting nozzle orifice sizes and flow rates: chart, bucket test and pressure</title><link>https://mistguide.com/nozzles/orifice-sizes-and-flow-rates/</link><guid>https://mistguide.com/nozzles/orifice-sizes-and-flow-rates/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>At 1,000 psi, common high-pressure misting nozzles flow about 0.012 GPM (0.006 in orifice), 0.016 GPM (0.008 in), 0.025 GPM (0.012 in) and 0.055 GPM (0.020 in). These are planning midpoints: published charts differ by up to about 40%, so confirm with a timed bucket test and scale for other pressures with the square root of the pressure ratio.</description></item>
<item><title>Misting nozzle threads and fittings: 10-24 vs 12-24, NPT adapters and more</title><link>https://mistguide.com/nozzles/nozzle-threads-and-fittings/</link><guid>https://mistguide.com/nozzles/nozzle-threads-and-fittings/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Most misting nozzles use a 10-24 UNC thread (0.190 in diameter, 24 threads per inch); many others use 12-24 (0.216 in, also 24 per inch). They look almost identical but are not interchangeable. Adapters convert nozzles to 1/8 in NPT pipe threads. Nozzles seal on an O-ring, not on the threads, so they need no tape.</description></item>
<item><title>Misting nozzle spacing and layout: spacing, height, angles, wind and zones</title><link>https://mistguide.com/nozzles/nozzle-spacing-and-layout/</link><guid>https://mistguide.com/nozzles/nozzle-spacing-and-layout/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Space high-pressure misting nozzles 18-24 in (45-60 cm) apart and mount them about 8-10 ft (2.4-3 m) high, angled slightly outward and down toward the area you want cooled. Low-pressure nozzles go 24-36 in apart, mounted high. Put the line on the upwind side, split large or wind-exposed areas into zones, and size the pump for the zones that run together.</description></item>
<item><title>Misting nozzle materials: brass, stainless steel, ceramic inserts and plastic</title><link>https://mistguide.com/nozzles/nozzle-materials/</link><guid>https://mistguide.com/nozzles/nozzle-materials/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Brass is the standard misting nozzle material and works well on ordinary treated municipal water. Stainless steel (316 for chlorides) lasts longer in aggressive, very soft or reverse-osmosis water, coastal air and pool areas. Ceramic orifice inserts resist wear so flow stays consistent. Plastic suits low-pressure hose systems only. No material prevents mineral scale.</description></item>
<item><title>Misting nozzle guide: what is inside a nozzle and how to choose one</title><link>https://mistguide.com/nozzles/misting-nozzle-guide/</link><guid>https://mistguide.com/nozzles/misting-nozzle-guide/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A misting nozzle is a threaded tip that forces pressurized water through an orifice 0.006-0.020 in wide and breaks the jet into droplets with an impingement pin or a swirl chamber. Choose by matching the nozzle to your pressure class first, then orifice size to your pump, then anti-drip, material and thread.</description></item>
<item><title>Anti-drip misting nozzles: how the check valve works and how to stop drips</title><link>https://mistguide.com/nozzles/anti-drip-nozzles/</link><guid>https://mistguide.com/nozzles/anti-drip-nozzles/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>An anti-drip misting nozzle has a small spring-loaded check valve behind the orifice that closes when line pressure falls below its opening pressure, commonly in a roughly 10-40 psi range. It stops water draining out of the line after shutdown, but a truly drip-free system also needs line pressure to drop quickly, usually via a pressure release valve at the pump.</description></item>
<item><title>Winterizing a misting system: preventing freeze damage and restarting in spring</title><link>https://mistguide.com/maintenance/winterizing-a-misting-system/</link><guid>https://mistguide.com/maintenance/winterizing-a-misting-system/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>To winterize a misting system, shut off and drain the supply, remove or open the nozzles and end plugs, blow the lines out with low-pressure air, drain the filter housing, and drain the pump and store it as its manufacturer directs, often indoors or protected with non-toxic antifreeze. Do it before the first freeze, not after.</description></item>
<item><title>Water hygiene and Legionella in misting systems</title><link>https://mistguide.com/maintenance/water-hygiene-and-legionella/</link><guid>https://mistguide.com/maintenance/water-hygiene-and-legionella/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Legionella bacteria can grow in water that sits stagnant and warm, and misters can spread them because they make droplets people breathe in. CDC lists misters among devices linked to Legionnaires&#x27; disease. The controls are simple: do not leave water sitting in lines, flush to a drain before misting, drain when idle, keep filters clean, and disinfect as the manufacturer directs.</description></item>
<item><title>Misting system maintenance schedule by system type and water hardness</title><link>https://mistguide.com/maintenance/misting-system-maintenance-schedule/</link><guid>https://mistguide.com/maintenance/misting-system-maintenance-schedule/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A misting system needs a quick weekly visual check in season, monthly filter and nozzle inspections, a full start-up and shutdown each season, and an annual overhaul. High-pressure systems add plunger pump oil changes by operating hours. Hard water shortens every nozzle interval: above about 7 grains per gallon, plan to descale several times a season.</description></item>
<item><title>How to descale misting nozzles without damaging them</title><link>https://mistguide.com/maintenance/how-to-descale-misting-nozzles/</link><guid>https://mistguide.com/maintenance/how-to-descale-misting-nozzles/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>To descale misting nozzles, remove them, soak them in white vinegar (about 5% acetic acid) or a citric acid solution for several hours or overnight, rinse, blow them out backward with low-pressure air, and bucket test before reinstalling. Never push a pin or wire through the orifice: it enlarges the hole and ruins the spray.</description></item>
<item><title>Hard water and water treatment for misting systems</title><link>https://mistguide.com/maintenance/hard-water-and-water-treatment/</link><guid>https://mistguide.com/maintenance/hard-water-and-water-treatment/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Hard water, above about 7 grains per gallon (120 mg/L as CaCO3), leaves calcium scale in misting nozzles and white spots on surfaces. A polyphosphate scale inhibitor slows nozzle scaling but does not stop spotting. A softener stops hard scale but still leaves sodium residue. Only reverse osmosis removes most dissolved solids, so it is the choice when spotting matters.</description></item>
<item><title>Misting system water supply and filtration: pressure, backflow and filters</title><link>https://mistguide.com/installation/water-supply-and-filtration/</link><guid>https://mistguide.com/installation/water-supply-and-filtration/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>A high-pressure misting pump needs cold water at positive inlet pressure (typically 20-60 psi), supply flow well above the pump&#x27;s rating, an approved backflow preventer, and a 5 micron sediment filter before the pump. Low-pressure kits need 40-80 psi and a 100-200 mesh screen. Add shutoffs for servicing and drain points at low spots.</description></item>
<item><title>Misting system mounting height and placement: how high and where to aim</title><link>https://mistguide.com/installation/mounting-height-and-placement/</link><guid>https://mistguide.com/installation/mounting-height-and-placement/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>Mount high-pressure misting nozzles about 8-10 ft (2.4-3 m) high, 18-24 in apart, on the upwind edge of the space, aimed slightly outward and down. Low-pressure nozzles should go as high as the structure allows. Larger orifices, humid air and still conditions all call for more height or a fan.</description></item>
<item><title>Misting tubing types: nylon, copper, stainless steel and poly compared</title><link>https://mistguide.com/installation/misting-tubing-types/</link><guid>https://mistguide.com/installation/misting-tubing-types/</guid><pubDate>Mon, 28 Sep 2026 00:00:00 +0000</pubDate><description>High-pressure misting systems use 3/8 in OD tubing rated for at least 1,000 psi at operating temperature: nylon for low-cost DIY runs, copper for a neater, sun-tolerant permanent install, and stainless steel for commercial or coastal sites. 1/4 in poly or vinyl is only for low-pressure hose systems.</description></item>
</channel></rss>
